UPS Systems (UPS)

323
Uninterruptible Power Supplies for desktops, network gear and servers. The selection covers offline UPS units for basic protection, line-interactive units that handle voltage sags and surges without using the battery, and online double-conversion UPS systems that fully isolate sensitive equipment from mains disturbances. Listings show output capacity, runtime estimates, outlet count and management options so the unit matches the load.
Loading...
POWERWALKER VI 600 CSW FR UPS
Special offer
€179.46 / incl. VAT 148.31 / excl. VAT
POWERWALKER VI 850 SH UPS
Special offer
€100.32 / incl. VAT 82.91 / excl. VAT
EATON 9PX 3000i RT3U
Special offer
MPN: 9PX3000IRT3U EATON 9PX 3000i RT3U
€3,201.66 / incl. VAT 2646 / excl. VAT
POWERWALKER UPS Rack VFI 10000 RTG PF1
Special offer
€2,901.97 / incl. VAT 2398.32 / excl. VAT
QOLTEC 53978 UPS Monolith 650VA 360W LCD
Special offer
€99.33 / incl. VAT 82.09 / excl. VAT
QOLTEC 53945 UPS 1KVA
Special offer
€270.75 / incl. VAT 223.76 / excl. VAT
QOLTEC 53038 Battery AGM 12V 100Ah
Special offer
€174.65 / incl. VAT 144.34 / excl. VAT
BATTERY 12V 12AH VRLA/AM12-12 ACUMAX EMU
Special offer
€39.51 / incl. VAT 32.65 / excl. VAT
BATTERY 12V 7.2AH VRLA/EP7.2-12 T2 EUROPOWER EMU
Special offer
€30.30 / incl. VAT 25.04 / excl. VAT

Items 1-12 of 323

Category overview

A UPS keeps equipment running through outages, sags and spikes long enough for the system to either ride out the event or shut down cleanly. The right unit depends on the connected load, the desired runtime, and how clean the mains supply needs to be at the equipment.

What this category covers

Offline (standby) UPS units for office PCs and home networks; line-interactive units that handle voltage variation without switching to battery; online double-conversion UPS systems for servers and sensitive equipment that cannot tolerate any switchover.

How to choose a UPS

Size by real watts, not just VA

UPS units are often labelled in volt-amperes (VA) and watts. The watt figure is the meaningful one for sizing modern equipment, which has switching power supplies. Add the rated wattage of everything that will run on the UPS, then choose a unit comfortably above that, ideally with a 25 to 30 percent margin.

Decide on runtime

For automatic shutdown, 5 to 10 minutes is usually enough. For ride-through to a generator, the UPS only needs to last a few seconds. For longer outages without a generator, larger battery packs or external battery cabinets are required, and the cost rises quickly.

Choose the topology

Offline UPS units stay out of the way and switch to battery only when the mains fails. Line-interactive units regulate voltage continuously and are more tolerant of poor mains. Online double-conversion UPS systems run the load entirely from the inverter, providing a clean, stable output regardless of mains quality.

Plan management

USB or serial communication is enough for a single UPS feeding one or two computers. Network-managed UPS units allow multiple servers to monitor status and shut down in coordinated fashion. For unattended sites, network management is usually a hard requirement.

Key features to compare

Outlet count and type

Smaller UPS units use country-specific outlets; rack and server-class units use IEC C13 and C19 outlets. Pick a model with the right outlet types and enough of them for the actual equipment.

Hot-swappable batteries

For UPS units that protect critical equipment, hot-swappable battery packs let the batteries be replaced without taking the load offline. This matters far more in server rooms than in offices.

Cold start

Cold start lets the UPS power equipment from battery even when no mains is present at boot time, which is useful for portable applications and for testing.

What to check before buying

  • What is the total watt load of equipment to be protected, including future additions?
  • How long does the runtime have to be: shutdown time, ride-through to a generator, or longer?
  • Is offline, line-interactive or online double-conversion required by the equipment?
  • Are USB or network management features required for monitoring?
  • Is the form factor (tower or rack-mount) right for the install location?

Frequently asked questions

How do I know if I need an online UPS?

Online double-conversion UPS systems are needed when equipment cannot tolerate any switchover transient and when mains quality is poor or unstable. Critical servers, medical equipment and some lab gear fall into this category. For typical office PCs and most home networks, line-interactive or offline UPS units are enough.

Will my UPS protect against lightning?

UPS units include surge protection that handles typical mains spikes. A direct or near-direct lightning strike can exceed any consumer-class device's protection. For sites at high lightning risk, additional facility-level surge protection at the panel is required, in addition to the UPS.

How do I make my computer shut down automatically when the battery is low?

Connect the UPS to the computer over USB and install the manufacturer's monitoring software. Most software packages support a configurable battery threshold or remaining-time threshold at which the operating system shuts down cleanly. For multiple servers on one UPS, network management software coordinates shutdown across them.

Why do my UPS batteries fail so quickly?

Heat is the main enemy of lead-acid UPS batteries. Running a UPS in a hot equipment room halves expected battery life. Frequent deep discharges also shorten life. A UPS in a cool, ventilated location with infrequent outages routinely reaches its full battery lifespan.

Can I use a UPS with a laser printer?

Laser printers draw very high inrush current when the fuser warms up and can overload a UPS sized for office gear. Manufacturers usually recommend not connecting laser printers to a UPS, or using a separate, large unit specifically rated for printer loads.